| Customization: | Available |
|---|---|
| Metal Coating: | Copper |
| Mode of Production: | SMT |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
| Details | Min. | Typ. | Max | Error | Unit |
| Battery | |||||
| Battery type ( | LiFePO4 | ||||
| Battery Series | 4S | ||||
| Absolute Maximum Rating | |||||
| Input Charging Voltage | 14.6 | V | |||
| Input Charging Current | 5 | 6 | A | ||
| Output Discharging Current | 20 | 22 | A | ||
| Ambient Condition | |||||
| Operating Temperature | -20 | 25 | 65 | ºC | |
| Humidity (No Water-Drop) | 0% | RH | |||
| Protection Parameters (for Individual Cell). | |||||
| Over-Charge Voltage Protection (OVP) | 3.650 | ±25mV | V | ||
| Over-Charge Voltage Protection Release (OVPR) | 3.600 | ±25mV | V | ||
| Over-Discharge Voltage Protection (UVP) | 2.800 | ±25mV | V | ||
| Over-Discharge Voltage Protection Release (UVPR) | 2.850 | ±25mV | V | ||
| Over-Current Discharge Protection (OCDP) | 50 | 60 | 70 | A | |
| Over-Current Protection Delay Time (OCPDT) | 31 | mS | |||
| Over-Current Discharge Protection Release | Cutoff Load | ||||
| Short circuit current protection | 80 | A | |||
| Short circuit current protection delay time | 122 | uS | |||
| Short circuit protection Release | Cutoff Load | ||||
| Over Temperature | 55 | 60 | 65 | ºC | |
| Cell balance | |||||
| BleedStartPoint | / | V | |||
| BleedAccuracy | / | mV | |||
| BleedCurrent | / | / | / | mA | |
| Balance Mode | / | ||||
| Current Consumption | |||||
| Operation mode | 140 | 200 | uA | ||
| GasGauge Information | |||||
| Voltage(Note) | 13.200 | ±0.020 | V | ||
| Current(Note) | 1000 | ±5 | mA | ||
| FCC(Note) | 13800 | mAh | |||
| RM(Note) | 0 | mAh | |||
| Manufacture Name | |||||