| Customization: | Available |
|---|---|
| Metal Coating: | Copper |
| Mode of Production: | SMT |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
| No. | Test item | Criterion (Adjustable) |
||
| 1 | Voltage | Charging voltage | DC:29.4V CC/CV | |
| Balance voltage for single cell | 4.20±0.05V | |||
| 2 | Current | Balance current for single cell | 84±10mA | |
| Current consumption | ≤20μA | |||
| Maximal continuous charging current | 12A | |||
| Maximal continuous Discharging current | 12A | |||
| 3 | Over charge Protection | Over charge detection voltage | 4.25±0.025V | |
| Over charge detection delay time | 0.7S-1.3S | |||
| Over charge release voltage | 4.05±0.05V | |||
| 4 | Over discharge protection) | Over discharge detection voltage | 2.50±0.05V | |
| Over discharge detection delay time | 14mS-26mS | |||
| Over discharge release voltage | 3.0±0.1V | |||
| 5 | Over current protection | Over current detection voltage | 0.2±0.02V | |
| Over current detection current | 50±10A | |||
| Detection delay time | 8ms-16ms | |||
| Release condition | Cut load, Auto release | |||
| 6 | Short protection | Detection condition | Exterior short circuit | |
| Detection delay time | 200-500us | |||
| Release condition | Cut load, Auto release | |||
| 7 | Resistance | Protection circuitry | ≤30mΩ | |
| 8 | Temperature | Operating Temperature Range | -40~+70ºC | |
| Storage Temperature Range | -40~+70ºC | |||