No. | Test Item | Criterion | |
1 | Voltage | Charging voltage | DC:54.6V CC/CV |
Balance voltage for single cell | 4.20±0.05V | ||
2 | Current | Balance current for single cell | 67±5mA |
Current consumption for single cell | ≤100μA | ||
Maximal continuous charging current | 5A | ||
Maximal continuous Discharging current | 25A | ||
3 | Over charge Protection | Over charge detection voltage | 4.25±0.05V |
Over charge detection delay time | 0.5S-2S | ||
Over charge release voltage | 4.15±0.1V | ||
4 | Over discharge protection | Over discharge detection voltage | 2.75±0.1V |
Over discharge detection delay time | 10-200mS | ||
Over discharge release voltage | 3.0±0.1V | ||
5 | Over current protection | Over current detection voltage | 100±25mv |
Over current detection current | 60±10A | ||
Detection delay time | 5ms-60ms | ||
Release condition | Cut load, auto release | ||
6 | Short protection | Detection condition | Exterior short circuit |
Detection delay time | 200-800us | ||
Release condition | Cut load,auto release | ||
7 | Resistance | Protection circuitry | ≤20mΩ |
8 | Temperature | Operating Temperature Range | -40~+70ºC |
Storage Temperature Range | -40~+125ºC |