Metal Coating: | Copper |
---|---|
Mode of Production: | SMT |
Layers: | Single-Layer |
Base Material: | FR-4 |
Certification: | RoHS |
Customized: | Customized |
Customization: |
---|
Suppliers with verified business licenses
No. | Test Item | Criterion | ||||
1 | Voltage | Charging voltage | DC:16.8V CC/CV | |||
Balance voltage for single cell | ||||||
2 | Current | Balance current for single cell | ||||
Current consumption for single cell | ≤50μA | |||||
Maximal continuous charging current | 4A | |||||
Maximal continuous Discharging current | 4A | |||||
3 | Over charge Protection | Over charge detection voltage | 4.25±0.05V | |||
Over charge detection delay time | 0.5S-2S | |||||
Over charge release voltage | 4.15±0.1V | |||||
4 | Over discharge protection | Over discharge detection voltage | 2.5±0.1V | |||
Over discharge detection delay time | 10mS-200mS | |||||
Over discharge release voltage | 3.0±0.10V | |||||
5 | Over current protection | Over current detection current | 15±5A | |||
Detection delay time | 5-60mS | |||||
Release condition | Cut load, Auto Recovery | |||||
6 | Short protection | Detection condition | Exterior short circuit | |||
Detection delay time | 200-800us | |||||
Release condition | Cut load, Auto Recovery | |||||
7 | Resistance | Protection circuitry | ≤60mΩ | |||
8 | Temperature | Operating Temperature Range |
|
|||
Storage Temperature Range | -40~+125ºC |
Suppliers with verified business licenses